Product Details:
Payment & Shipping Terms:
|
Name: | Cut To Length Line Machine | Usage: | Cut To Length |
---|---|---|---|
Max Weight: | 5T | Max Width: | 1500mm |
Speed: | 0--100mm/min | Thickness: | 0.3-2.0mm |
High Light: | coil cutting line,sheet metal shearing machine |
Technical Parameter
Type | RB-650 |
Material Thickness Range to be Slit | 0.3--2.0mm |
Width Thickness Range to be slit | 200--600mm |
Inner Diameter of Feeding | 460--520mm |
Inner Diameter of Discharge | 480--508mm |
Max Outside Diameter | 1500mm |
Weight | 5t |
Cutting Speed | 0--100m/min |
Horizontal Beat | ±0.02mm |
Vertical Beat | ±0.02mm |
Main components
1. | Hydraulic coil Car | 1 unit |
2. | Hydraulic de-coiler | 1 unit |
3. | Looper 1 | 1 unit |
4 | Side guide device 1 | 1 unit |
5. | 4-High pre-leveling machine | 1 unit |
6. | Looper 2 | 1 unit |
7. | Side guide device 2 | 1 unit |
8. | Servo precise straightening machine | 1 unit |
9. | High speed shearing machine | 1 unit |
10. | Transportation table | 1 unit |
11. | Hydraulic lifting table | 1 unit |
12. | Pneumatic stacker device | 1 unit |
13. | Exit coil car | 1 unit |
14. | Pneumatic system | 1 set |
15. | Electrical control system | 1 set |
16. | Hydraulic Control System | 1 set |
Features:
1. Centralized control with CNC control system
2. The cutting length, speed, pieces designed & controlled by the program
3. Computer controls the whole process of leveling & shearing to compensate the error when it works automatically
4. The line can stop automatically when the need shearing number is reached
5. The line speed can be adjusted
6. Equips a gauge with high precision
1. Coil should be put right to keep the weight balanced. The coil car can reset only after fix and expand the coil into decoiler tightly.
2. First press the coil head by traction roll, then open the package of the coil, to prevent the coil head bounced off.
3. Operators shall not stand on the coil when machine running.
4. Do not move coil directly by hand.
5. Stop and check the machine units immediately when find fault. Only check out and correct, the machine can restart.
6. Do not remove or change circuit. In case has problem, please consult professional technicians.